{"id":538,"date":"2021-11-10T14:05:24","date_gmt":"2021-11-10T05:05:24","guid":{"rendered":"https:\/\/www.japan-pionics.co.jp\/?page_id=538"},"modified":"2021-11-10T14:05:24","modified_gmt":"2021-11-10T05:05:24","slug":"refine_ultla_p","status":"publish","type":"page","link":"https:\/\/www.japan-pionics.co.jp\/en\/products\/refine_gas\/refine_ultla_p\/","title":{"rendered":"Getter-type gas purifier MODEL-UHG\/URT"},"content":{"rendered":"<div id=\"pl-538\"  class=\"panel-layout\" ><div id=\"pg-538-0\"  class=\"panel-grid panel-has-style\" ><div class=\"page_con panel-row-style panel-row-style-for-538-0\" ><div id=\"pgc-538-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-538-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<ul>\n<li>Allows purification of gas to ultra-high purity temperatures with the aid of our originally developed getter.<\/li>\n<li>Allows removal of nitrogen(N2), which is difficult to remove by Normal-temperature adsorption purifiers.<\/li>\n<li>Indication of the total purified gas volume and the total purification time of the reaction column (getter), allow the operator to check the remaining purification capacity of the column.<\/li>\n<li>The getter lifetime is long. (URT: 20,000 hr UHG: 9,000 hr)<\/li>\n<li>Allows setting ON\/OFF the reaction column heater at predetermined timing with week-based operation programming.(URT type)<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-538-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-538-0-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.japan-pionics.co.jp\/page\/wp-content\/uploads\/products_refine_gas_p03.jpg\" alt=\"\" width=\"400\" height=\"400\" class=\"alignnone size-full wp-image-26\"><\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-538-1\"  class=\"panel-grid panel-has-style\" ><div class=\"page_con panel-row-style panel-row-style-for-538-1\" ><div id=\"pgc-538-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-538-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"2\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h4>Equipment specifications<\/h4>\n<div class=\"scroll\">\n<table summary=\"\u88c5\u7f6e\u4ed5\u69d8\" cellspacing=\"0\">\n<tbody>\n<tr>\n<th colspan=\"2\">Model<\/th>\n<td colspan=\"2\"><strong>UHG<\/strong><\/td>\n<td colspan=\"2\"><strong>URT<\/strong><\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\" rowspan=\"2\">Applicable gas<\/th>\n<td colspan=\"2\">H<span class=\"txt_s\">2<\/span><\/td>\n<td colspan=\"2\">Ar,He,Xe,etc.<\/td>\n<\/tr>\n<tr>\n<td>Inlet<\/td>\n<td>Outlet<\/td>\n<td>Inlet<\/td>\n<td>Outlet<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Max. pressure(MPa)<\/th>\n<td>0.8<\/td>\n<td>Under \u22bf0.1<\/td>\n<td>0.8<\/td>\n<td>Under&nbsp;\u22bf0.1<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\">Temp.(\u2103)<\/th>\n<td>5\uff5e35<\/td>\n<td>5\uff5e35<\/td>\n<td>5\uff5e35<\/td>\n<td>5\uff5e35<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"3\" width=\"16%\"><\/th>\n<th width=\"10%\">O<span class=\"txt_s\">2<\/span><\/th>\n<td width=\"13%\">5,000<\/td>\n<td width=\"24%\">\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<td width=\"13%\">100<\/td>\n<td width=\"24%\">\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th>CO<\/th>\n<td>1,000<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<td>100<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th>CO<span class=\"txt_s\">2<\/span><\/th>\n<td>500<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<td>100<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"5\">Impurities<br \/>\n(vol.ppb)<\/th>\n<th>H<span class=\"txt_s\">2<\/span><\/th>\n<td>-<\/td>\n<td>-<\/td>\n<td>100<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th>CH<span class=\"txt_s\">4<\/span><\/th>\n<td>100<\/td>\n<td>\u22665ppb Standard<br \/>\n\u203b1ppb Non-standard<\/td>\n<td>100<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th>N<span class=\"txt_s\">2<\/span><\/th>\n<td>5,000<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<td>5,000<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th>H<span class=\"txt_s\">2<\/span>O<\/th>\n<td>10,000<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<td>2,500<\/td>\n<td>\u22661ppb Standard<br \/>\n\u203b0.1 Non-standard<\/td>\n<\/tr>\n<tr>\n<th>Particle<\/th>\n<td><\/td>\n<td>\u22670.1\u00b5m<br \/>\n\u22661pcs\/0.0283m<sup>3<\/sup><\/td>\n<td><\/td>\n<td>\u22670.1\u00b5m<br \/>\n\u22661pcs\/0.0283m<sup>3<\/sup><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"page_con_p\">*Please consult with us about the available flow rates,<br \/>\n*The purification capacity for Models URT and UHG refers to the life expectancy of the getter. In practice, the getter remains effective for 20,000 hours(URT) or 9,000 hours (UHG) total operating time at the allowable maximum flow rate and inlet gas impurities listed above.<br \/>\nThe Getter reaction column cannot be regenerated and must be replaced when it reaches the lifetime.<br \/>\n(Please consult separately with us concerning use overseas.)<\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-538-2\"  class=\"panel-grid panel-has-style\" ><div class=\"page_con panel-row-style panel-row-style-for-538-2\" ><div id=\"pgc-538-2-0\"  class=\"panel-grid-cell\" ><div id=\"panel-538-2-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"3\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<h2>Related products<\/h2>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-538-3\"  class=\"panel-grid panel-has-style\" ><div class=\"cat_index_con panel-row-style panel-row-style-for-538-3\" ><div id=\"pgc-538-3-0\"  class=\"panel-grid-cell\" ><div id=\"panel-538-3-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"4\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-27\" src=\"https:\/\/www.japan-pionics.co.jp\/page\/wp-content\/uploads\/products_refine_gas_p02.jpg\" alt=\"\" width=\"400\" height=\"400\"><\/p>\n<ul>\n<li><a href=\"..\/..\/refine_gas\/refine_hydrogen\/\">Palladium alloy memrane permeation hydrogen gas purifier<\/a><\/li>\n<\/ul>\n<p class=\"cat_index_con_p\">Purifier based on selective permeation through a palladium alloy membrane that rejects permeation of any substance other than hydrogen.<\/p>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-538-3-1\"  class=\"panel-grid-cell\" ><div id=\"panel-538-3-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"5\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-27\" src=\"https:\/\/www.japan-pionics.co.jp\/page\/wp-content\/uploads\/products_refine_gas_p04.jpg\" alt=\"\" width=\"400\" height=\"400\"><\/p>\n<ul>\n<li><a href=\"..\/..\/refine_gas\/refine_air\/\">Normal-temperature adsorption air purifier<\/a><\/li>\n<\/ul>\n<p class=\"cat_index_con_p\">The JAR series of air purifier is primarily used for steppers, the zero gas for automobile emissions measurement, and fuel cell gas purification.<\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Allows purification of gas to ultra-high purity temperatures with the aid of our originally developed getter. Allows removal of nitrogen(N2), which is difficult to remove by Normal-temperature adsorption purifiers. Indication of the total purified gas volume and the total purification time of the reaction column (getter), allow the operator to check the remaining purification capacity [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":527,"menu_order":16,"comment_status":"closed","ping_status":"closed","template":"page_cat_products_refine_gas.php","meta":{"_locale":"en_US","_original_post":"https:\/\/www.japan-pionics.co.jp\/page\/?page_id=50","footnotes":""},"class_list":["post-538","page","type-page","status-publish","hentry","en-US"],"_links":{"self":[{"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/pages\/538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/comments?post=538"}],"version-history":[{"count":1,"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/pages\/538\/revisions"}],"predecessor-version":[{"id":539,"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/pages\/538\/revisions\/539"}],"up":[{"embeddable":true,"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/pages\/527"}],"wp:attachment":[{"href":"https:\/\/www.japan-pionics.co.jp\/wp-json\/wp\/v2\/media?parent=538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}